Can the Xsens Meter measure multiphase?
No, today it can only measure single and two phase flow.
What Diameter can the Meter handle?
1,5” to 30” (higher might be possible, but Xsens have to evaluate).
What is the watercut range, can it measure ppm range?
Range is 0-100% watercut, accuracy within +/-1% abs.
What is the temperature and Pressure limitations?
For pressure there is no limits. Temperature is 100 deg C at surface of pipe today.
Can the Meter measure gas? What about gas with some liquid within?
Yes, The Meter can measure gas and gas with up to at least 50 weight percentage liquid.
What kind of calibration is required?
At site Xsens need Speed of Sound of oil/condensate and the water or gas. This can be collected by measuring in zero flow situations or Xsens can measure such from samples taken. Alternatively, calibrate against two given flow rates. For complex piping configurations, shorth downstream/upstream length and requirements for highest possible accuracy, third party flowloop calibration can be done.
Is the Meter dependent on input of temperature?
If the Meter shall measure watercut, temperature is an important input. If process temperature is not available, such can be arrived from the internal temperature sensors mounted on the surface of the pipe inside the Meter.
How will changes in salinity influence the readings from the Meter?
Insignificant influence.
Can the Meter be moved from one pipe size to another?
No, the Meter is designed specially for each pipe sizes.
Does the Xsens gas Meter require updated PVT data?
No, if your wells are gas wells (with/without) small amounts of liquid we would like to have input on Pressure and temperature.
Is there a lower pressure range for your gas Meters?
We would like to have a minimum of 20 bar pressure where we install the Meters (Xsens can lower this by doing some extended calibrations).
Can the Meter measure sand?
No, this is a flow Meter not a sand detector.
Can the Meter be used in downstream applications?
Yes absolutely, it can basically measure anything that flows (water, chemicals, slurries, mud etc.)